ONE BATTERY CLUSTER · NINE NAMED MEMBERS

Nine RacksA battery through its records.

A number can stay the same while its members change. A recorded operation start need not be the first usable current observation. Explore what becomes visible when we keep the names, clocks and distances.

A guided exhibition, not the complete archive.

Each room uses a different set of previously examined records to open one question. The examples are illustrative, not a representative sample or a frequency estimate. See which operations appear in each room ↓

01 / THE BEGINNING

Where does “start” begin?

The operation label and the first usable current record are different coordinates. Neither alone identifies the physical onset.

First usable records, Rack by Rack

○ Voltage● Current

Position = seconds after the recorded operation start. Markers show first records only, not continuous support. The leading current zero was excluded by the existing segmentation rule.

Observed

Interpretation

The blank interval does not show that a Rack was idle, disconnected or late to participate. The first usable current record is an observation boundary.

Inspect the native clocks and selection

Both previously retained examples are available here. Source times are used as recorded; their time zone and acquisition-clock synchrony are not established. No new operation has been selected for this exhibit.

READ THE EXHIBIT WITH ITS BOUNDARIES

The records have a source.
The reading has a scope.

Source & transformation

Qu, Jingbo (2026), Dataset for: A Multi-Agent AI Framework for Explainable Battery System Maintenance, Zenodo, DOI 10.5281/zenodo.20094787. The record lists CC BY 4.0.

LFR selected and arranged the retained excerpts, custom summaries, ranks and current-band passages. This is not a reproduction of the authors’ analysis or an indication of their endorsement. Source material is supplied without warranties under its stated licence.

Related article: Qu et al., A multi-agent AI framework for explainable battery system maintenance. Its scientific conclusions are not evidence for the exhibit’s descriptions.

What is kept, what is unknown

Rack labels, stored values and native timestamps remain attached to each selection. Reported current is negative for charge and positive for discharge. Measurement accuracy, cross-Rack offsets, acquisition synchrony and original control logic are not established here.

Extra stored decimal places do not establish measurement accuracy. SOC summaries retain the source estimate; the temperature channel is not part of this exhibit.

The examples are selected, retrospective excerpts. They are not a complete operating history or an estimate of how frequently a pattern occurs. Descriptions do not become physical findings because they are interactive.

Different rooms, different selections

RoomRecorded operationsSelection purpose
01 · The beginning#130, #145Two retained examples of record-start support.
02 · Same summary#1, #349, #5, #350The first exact-summary match with changed member voltage in each previously selected operation.
03 · Order & distance#318, #333, #339, #350All selections in an existing nominal-Ah comparison set, with missing positions left blank.
04 · Current & voltage#4, #291A viewed charge bookmark and the longest retained discharge passage at the 5 A scale.
05 · After the record#30, #287Largest retained current decreases within a restricted boundary selection.

These are separate viewing selections, not one matched sample. All nine members remain attached to each displayed case. A broader local research explorer is not included in this public exhibit.

Public inspectability and limits

The exhibition’s selected record payload is delivered to your browser. It supports inspection of the served member records, voltage arithmetic and selections. The current and reported-SOC summary medians are precomputed retained values; their underlying per-member inputs are not served, so those medians cannot be independently recomputed from this exhibit. It is not a public end-to-end replay of the complete LFR analysis. Read the selection and method notes.

Unsupported positions remain blank. All nine members are retained in each displayed case. No raw monthly MAT files or complete internal research archive are served here.